Model: DM6011
Environment condition of using:
CAT.II 600V
Pollution level: 2
Altitude < 2000m
Working environment temperature and humidity:
0~40°C (<80% RH, <10°C non condensing)
Storage environment temperature and humidity -10~60°C (70% RH, remove the battery)
Temperature coefficient: 0.1 x accuracy / °C (<18°C or >28°C)
Maximum Voltage between terminals and earth ground: 600V
Sampling rate: about 3 times / second
Display: 4000 counts
Over range indication: it displays " OL"
Low battery indication: will be displayed
Input polarity indication: automatically display
Power requirements: 2 x 1.5v battery
ACCURACY SPECIFICATION
The accuracy applies within one year after the calibration
Reference condition: the environment temperature 18°C to 28°C, the relative humidity is no more than 80%, accuracy: ± (%reading + word)
Power supply 2 x AAA